Which regulations apply to a battery hazardous materials warehouse?
The decisive rules are the German Hazardous Substances Ordinance with TRGS 510, water law with the AwSV (WGK 3, firefighting water retention) and the ADR regulations for Class 9 dangerous goods. On top of these come fire protection and early detection requirements from building law and insurers. The European Battery Hub maps these requirements structurally, technically and organizationally and backs them with certificates such as ADR, DIN EN ISO 9001 and DIN EN ISO 14001.
Read more: TRGS 510 and storage classes for lithium batteries, Insurable battery warehouse
What is the difference between a hazardous materials warehouse and a hazardous substances warehouse?
"Dangerous goods" is a transport law term: for road transport, the ADR regulations govern which substances and articles may be carried and how. "Hazardous substances" is an occupational safety term; in Germany, their storage is governed by the Hazardous Substances Ordinance and TRGS 510, water protection by the AwSV. Lithium-ion batteries are class 9 dangerous goods and are handled in the warehouse according to TRGS 510 and the risk assessment. In everyday usage, the two terms are often used interchangeably.
Read more: TRGS 510 and storage classes for lithium batteries, Dangerous goods transport under ADR
Does a hazardous materials warehouse require a permit?
Whether a warehouse for dangerous substances needs a permit depends on building law and, above certain quantities, on the German Federal Immission Control Act (BImSchG). The permit is required by the warehouse operator. If you store your batteries at the European Battery Hub, you do not need a permit of your own.
Where must lithium batteries not be stored?
TRGS 510 rules out places where storage can endanger people, such as traffic routes like stairwells, corridors and escape and rescue routes, as well as break rooms and sanitary facilities. For larger quantities of lithium-ion batteries, the property insurer's requirements also apply, for example separation distances from combustible material or a fire-resistant partition.
Read more: TRGS 510 and storage classes for lithium batteries, Insurable battery warehouse
Which batteries may go into a hazardous materials warehouse?
We store undamaged lithium-ion cells, modules, packs and large-scale energy storage, from automotive and battery manufacturing through stationary energy storage (BESS) to batteries from e-mobility. For each item we need the safety data sheet and the UN 38.3 test summary. At the inbound inspection gate, batteries pass a temperature check; goods too large for the gate go through their own goods receipt processes. We do not store damaged batteries; we arrange their collection and transport through a specialized partner, in the battery containment box where needed.
Read more: Car manufacturers, Battery manufacturers, E-mobility
What do WGK 3 and dangerous goods Class 9 mean for battery storage?
WGK 3 is the highest water hazard class under the German AwSV ordinance based on the Water Resources Act. A warehouse designed for such substances must retain contaminated firefighting water by design. Dangerous goods Class 9 (M4), with the UN numbers UN3480 (batteries on their own) and UN3481 (in or with equipment), classifies lithium-ion batteries as dangerous goods and governs labeling, handling and transport under the ADR. At the European Battery Hub both requirements are implemented structurally and organizationally.
How are defective batteries handled in the hazardous materials warehouse?
The European Battery Hub does not store damaged, defective or returned batteries in the hazardous materials warehouse. They can only be kept in the battery containment box (Liio-Box), covered by BAM specification 15854, which withstands up to 1,240 °C inside and a maximum of 52 °C outside. We arrange their removal through a specialized partner.
Read more: Battery containment box, Defective batteries (DDLB)
Is the hazardous materials warehouse insurable?
The groundwork is in place: fire suppression is designed to FM Global for hazardous materials, backed by a fire water tank holding around 1 million liters for the sprinkler system and fire water retention inside the hall. Which conditions insurers set and what the European Battery Hub has in place for them is explained on the insurable battery warehouse page.