Why an insurable battery warehouse decides the economics

An insurable battery warehouse is a lithium-ion storage facility that demonstrably meets the fire protection and documentation requirements of its property insurer. As a purpose-built new facility, the European Battery Hub (EBH) in Paderborn, Germany, provides the structural basis for this: sprinkler and rack technology to FM Global, meaning the specific requirements of this insurer, around 1 million liters of firefighting water for the sprinkler system, sealed hall floors with a fire water barrier, zoned storage and an emergency response plan.

Whether a lithium-ion stock can be insured on acceptable terms often decides whether storing it pays off. Germany has little specific statutory law for lithium-ion storage; the rules that bind in practice come from the insurers’ codes and become binding obligations through the insurance contract. The statutory rules for storage itself (TRGS 510, AwSV, ADR) are explained on the page hazardous materials warehouse for batteries. The EBH’s records are backed by standards and certificates, verifiable rather than merely claimed.

Note: this overview is not legal or insurance advice. The binding assessment of your specific risk is carried out by your property insurer or its risk engineer together with our team.

Fundamentals

What insurers require

Property insurers assess a lithium-ion warehouse against a coordinated fire protection concept. At its core is a reliable, early-triggering automatic fire suppression system matched to the stored goods and their packaging: sprinklers work above all through strong cooling. Water cools and stops the spread of a thermal runaway, but it does not reliably end the reaction in the affected cell. The GDV stresses that protection improves the earlier the system triggers and the more completely it cools the stored goods with water. How the European Battery Hub applies this is explained in How to store lithium batteries safely.

Further core requirements from the insurers' codes:

  • Fire water retention: contaminated fire water from lithium-ion fires must be retained; the retention volume is sized through a fire protection and retention concept (protection of groundwater and surface water).
  • Zoning and separation distances: per VdS 3103, structural fire-resistant separation or minimum distances to combustible material, depending on the performance class and the fire suppression system; small fire compartments with a high fire resistance rating and quantity limits.
  • Multi-stage early detection: the state of the art combines off-gas, smoke and temperature detection with alarm forwarding to a permanently staffed location.
  • Inspected goods at receipt: only undamaged cells with UN 38.3 evidence (VdS 3856); limited state of charge (SoC) as specified by the insurer and the DGUV.
  • Handling of defective cells: separate quarantine in approved steel safety containers, monitored separately and kept at a distance from normal stock (see defective and damaged batteries).
  • Records and obligations: an agreed fire protection concept (VdS 3103/3856 or FM DS 7-112), maintenance and inspection records, storage under TRGS 510.

Anyone who can demonstrably meet these requirements improves the risk profile of battery storage, and with it terms, deductibles and the insurability of the goods. More on the full chain in battery logistics.

Insurer requirements

What insurers require, and how the EBH delivers.

01 / 09

Effective automatic fire suppression with full cooling, early-triggering

Fire suppression to FM Global for hazardous materials, matched to stored goods and packaging.

  1. Fire suppression to FM Global for hazardous materials, matched to stored goods and packaging.
  2. Fire water tank holding around 1 million liters for the sprinkler system.
  3. Retention inside the hall: sealed floors and a fire water barrier.
  4. Zoned storage in the KfW 40 new build, designed from the ground up for lithium-ion batteries.
  5. Fire alarm system and gas detection, plus a round-the-clock thermal imaging check by drone.
  6. Inbound inspection gate with temperature checks, separate goods receipt processes for oversized goods; safety data sheet and UN 38.3 test summary for each item.
  7. No storage of damaged batteries; suspect cells go into the battery containment box (Liio-Box) with BAM specification 15854, up to 1,240 °C inside, max. 52 °C outside.
  8. Hazardous materials warehouse designed for WGK 3, Class 9 (M4), UN3480/UN3481.
  9. ADR, DIN EN ISO 9001 and DIN EN ISO 14001.

Anyone who can prove they meet these requirements improves the risk profile of battery storage, and with it the terms, deductibles and insurability of the goods.

Your advantage

What this means for your balance sheet

01

Lower loss risk

FM Global sprinklers, temperature checks at goods receipt, a fire alarm system, gas detection and the round-the-clock thermal imaging check by drone reduce the likelihood that a thermal runaway starts and spreads, the basis of every good risk.

02

Better insurability of your goods

Fire suppression to FM Global for hazardous materials and complete records make it easier to underwrite your lithium-ion stock and can have a favorable effect on terms and deductibles.

03

Complete records

Fire protection concept, goods receipt records, maintenance and inspection evidence and certificates are documented. What your insurer needs for underwriting and claims settlement, we put together on request and after internal review.

04

Liability and business continuity

Certified safety in a new build eases the management's position on liability questions and protects both your ability to deliver and your investment against the loss of a single site.

Contacts

Your contacts

Talk directly with our business development team.
We will get back to you within 24 hours on business days.

FAQ

Frequently asked questions about the insurable battery warehouse

What must a lithium-ion battery warehouse meet in order to be insurable?

A lithium-ion battery warehouse becomes insurable through a fire protection concept agreed with the property insurer, following VdS 3103, VdS 3856 and FM Global DS 7-112. The core conditions include small, fire-resistant fire compartments, an early-triggering automatic fire suppression system with full cooling, fire water retention, multi-stage early detection combining off-gas, smoke and temperature, and, at goods receipt, exclusively undamaged, UN 38.3 inspected goods. The European Battery Hub is a KfW 40 new build designed from the ground up for lithium-ion batteries, with FM Global sprinklers for hazardous materials, around 1 million liters of fire water for the sprinkler system and fire water retention inside the hall. Which conditions apply in each case is agreed between your insurer and our team.

Read more: Hazardous materials warehouse for batteries, TRGS 510 and storage classes for lithium batteries

What distances does VdS 3103 require between lithium-ion batteries and combustible material?

VdS 3103 assesses lithium-ion batteries according to their performance. Depending on the performance class, it requires structural fire-resistant separation, separate storage or minimum distances to combustible material; whether an automatic fire suppression system is present affects the requirements. The specific values follow from the wording of VdS 3103 and the agreement with your insurer. At the European Battery Hub, batteries are stored in zones under fire suppression to FM Global.

To which standards is the fire suppression designed, and how much fire water is available?

The fire suppression system at the European Battery Hub is designed to FM Global for hazardous materials and matched to the stored goods and packaging. A fire water tank holding around 1 million liters supplies the sprinkler system. Water cools and stops the spread, but it does not reliably end the reaction in the affected cell. The rule is therefore: cool and isolate the battery. Contaminated fire water stays inside the hall: the floors are sealed, and a fire water barrier is added. This protects soil and water.

Read more: Thermal runaway, How to store lithium batteries safely

How does an insurable battery warehouse handle defective or suspect batteries?

Property insurers require that damaged or suspect cells be quarantined and monitored separately from normal stock in approved containers. The European Battery Hub therefore does not store damaged batteries; if a battery shows anomalies, it goes into the battery containment box (Liio-Box), which is covered by BAM specification 15854 and withstands up to 1,240 °C inside and a maximum of 52 °C outside. We arrange its removal through a specialized partner. For more detail, see the page on defective, damaged and returned batteries (DDLB).

Read more: Defective batteries (DDLB), Battery containment box

What happens in the event of a loss if the insurer's conditions were not met?

The conditions set by property insurers are contractual obligations. If an obligation is breached through gross negligence, the insurer may reduce the indemnity in proportion to the severity of the fault; in the case of a deliberate breach, it may be released from payment entirely. At the underwriting stage there is also the threat of tight sublimits, premium surcharges or an exclusion of cover for lithium-ion. A loss is only settled smoothly when the agreed conditions have been met and documented. We therefore record the fire protection concept, goods receipt, maintenance and inspections throughout, verifiable for underwriting and claims settlement.

What records do customers receive for their insurance?

We do not hand out records automatically, but on request and after internal review. They can include the documentation that insurers require for underwriting and claims settlement: the agreed fire protection concept, incoming goods and visual inspection records with UN 38.3 reference, maintenance and inspection evidence for the suppression and monitoring technology, and the ADR, DIN EN ISO 9001 and DIN EN ISO 14001 certificates. The specific set of records is agreed case by case with the customer and their property insurer. Our team supports the insurer's risk engineer during the assessment and responds on business days within 24 hours of a request.

Your lithium-ion stock, stored insurably

Talk to our team about your storage, fire protection and documentation concept. We respond within 24 hours on business days.

Response
within 24 hours on business days