Contact
Energy stored. Future delivered.

UN 38.3: The Eight Tests

UN 38.3 is the required transport test for lithium batteries. This guide explains the eight tests T1 to T8 and the exceptions.

At a glance

What is UN 38.3, and why is it mandatory?

UN 38.3 is a type test for lithium batteries (since ADR 2025 also sodium-ion): every cell and battery type must pass the required tests T1 to T8 before regular carriage as Class 9 dangerous goods. Testing is done by a test laboratory on behalf of the manufacturer; the European Battery Hub (EBH) in Paderborn, Germany, transports tested batteries and advises on the exceptions.

It is not a product quality test but a transport safety test. It makes sure a battery withstands low pressure, temperature changes, vibration, shocks and electrical faults without fire, rupture, leakage or a short circuit. The ADR regulations (road), RID (rail), the IMDG Code (sea) and the IATA DGR (air) all require it.

The evidence is the test summary, which manufacturers and subsequent distributors must make available (ADR 2.2.9.1.7.1 (g), clarified in ADR 2025). It is often called a "UN 38.3 certificate", but it is not a certification issued by an authority or certification body.

Which eight tests does UN 38.3 include?

The tests are run in a fixed order on the same test samples. T1 to T5 are carried out one after another on the same sample, T6 to T8 on further samples. The values below are typical test conditions from the UN Manual.

T1

Altitude simulation

What is tested

Behavior at low air pressure (for example air freight in an unpressurised cargo hold)

Typical test condition

11.6 kPa, at least 6 hours at 20 °C

T2

Thermal test (temperature cycling)

What is tested

Stress from rapid, extreme changes in temperature

Typical test condition

Cycling between +72 °C and -40 °C, 10 cycles

T3

Vibration

What is tested

Vibration during transport

Typical test condition

Sine sweep 7 Hz to 200 Hz and back, 3 hours per axis, 3 axes

T4

Shock (mechanical shock)

What is tested

Impacts from handling and transhipment

Typical test condition

e.g. 150 g / 6 ms (small cells), each direction and axis

T5

External short circuit

What is tested

Reaction to an external short circuit

Typical test condition

≤ 0.1 Ω at 57 °C, then 6 hours of observation

T6

Impact / crush

What is tested

Internal short circuit from deformation of the casing

Typical test condition

Impact: 9.1 kg from 61 cm, for cylindrical cells of 18 mm diameter or more. Crush up to 13 kN, for prismatic, pouch, coin and cylindrical cells under 18 mm

T7

Overcharge

What is tested

Behavior during overcharge

Typical test condition

Twice the recommended charging current, 24 hours, 7 days of observation

T8

Forced discharge

What is tested

Behavior during deep discharge / reverse polarity

Typical test condition

Forced discharge of the cell (cell test)

Test scope

Which tests apply to cells and batteries?

Not every test item goes through all eight tests.

Test itemTests
CellsT1 to T6 and T8
Rechargeable batteriesT1 to T5 and T7
Primary batteries (non-rechargeable)T1 to T5
UN 38.3

Eight tests before a battery may travel.

01 / 08

Altitude simulation

Only when a cell or battery type passes the required tests T1 to T8 may it be carried as regular Class 9 dangerous goods.

How do tests T1 to T8 work?

T1: Altitude simulation

The test sample is exposed to a low pressure of 11.6 kPa for at least six hours, which corresponds to an altitude of about 15,000 meters. This simulates transport in an unpressurised cargo hold. No leakage, venting, rupture or ignition is permitted.

T2: Thermal test

The battery goes through ten cycles of rapid change between +72 °C and -40 °C. This checks the seal and the mechanical integrity under thermal stress. Large cells and batteries dwell longer at each temperature step.

T3 and T4: Vibration and shock

In the vibration test, the sample goes through a sine sweep from 7 Hz to 200 Hz and back, three hours each in three mutually perpendicular axes. In the shock test, defined shock pulses are applied in the positive and negative direction of every axis. Both reproduce the stresses from the vehicle, transhipment and handling.

T5: External short circuit

The battery, conditioned to 57 °C, is short-circuited through a resistance of no more than 0.1 ohm and then observed for at least six hours. The external temperature must not exceed 170 °C, and no disassembly, rupture or ignition is permitted.

T6: Impact / crush

Here an internal short circuit is forced by mechanical deformation. In the impact test, a 9.1 kg mass is dropped from 61 cm onto the cell; this applies to cylindrical cells of 18 mm diameter or more. Prismatic, pouch, coin and cylindrical cells under 18 mm in diameter are crushed up to 13 kN instead. The surface temperature must not exceed 170 °C.

T7 and T8: Overcharge and forced discharge

The overcharge test (for rechargeable batteries only) checks behavior when charging at twice the recommended current for 24 hours, followed by seven days of observation. The forced discharge test (cells) checks deep discharge and reverse polarity. No fire may occur within seven days.

Shipping carton with a class 9 hazard label next to a document folder representing the UN 38.3 test summary (AI-generated visualization)

What is the test summary?

Since 1 January 2020, manufacturers and subsequent distributors of cells and batteries have had to make a test summary available (ADR 2.2.9.1.7.1 (g), clarified in ADR 2025). It states, among other things, the battery type, watt-hours or lithium content, the tests carried out, the edition of the UN Manual applied and the test laboratory.

In logistics, it is the entry ticket: without a test summary, a battery cannot be carried as regular UN 3480 or UN 3481. If it is missing, we work out with you which documents the manufacturer needs to provide or whether an exception applies.

Validity

When does a battery need to be retested?

A UN 38.3 test has no expiry date. A new test is required when the type changes. Section 38.3.2.2 of the UN Manual lists, among other things, a change in nominal energy of more than 20%, an increase in nominal voltage of more than 20% and changes to the cell chemistry, design or protection circuit that may affect the test result. What matters is that the tested type and the type shipped are the same.

Checklist

How do you check a test summary in 5 minutes?

Under section 38.3.5 of the UN Manual, every test summary includes:

  1. 1The name and contact details of the manufacturer
  2. 2The name and address of the test laboratory
  3. 3A unique test report number
  4. 4The date of the test report
  5. 5A description of the cell or battery, such as mass, watt-hours and chemistry
  6. 6The list of tests carried out, with results
  7. 7The edition (revision) of the UN Manual applied
  8. 8A signature with name and title
Special routes

When is no UN 38.3 test required?

  • Special provision 310: pre-production prototypes carried for testing and production runs of no more than 100 cells or batteries, packed to P910 or LP905. Important for battery manufacturers in development.
  • Special provision 376: damaged or defective batteries that no longer conform to the tested type, packed to P908 or LP904; critically defective ones to P911 or LP906 or under BAM conditions. More in our defective batteries guide.
  • Special provision 377: batteries for disposal or recycling, packed to P909, for example on their way to recyclers.

Since ADR 2025, UN 38.3 also applies to sodium-ion batteries.

Contacts

Your contacts

Talk directly with our business development team.
We will get back to you within 24 hours on business days.

FAQ

Common questions about UN 38.3

What is UN 38.3, and is it mandatory?

Yes. UN 38.3 is the transport test for lithium batteries from the UN Manual of Tests and Criteria. The ADR regulations, RID, IMDG Code and IATA DGR all require every cell and battery type to have passed it before being carried as regular Class 9 dangerous goods. Special routes without testing exist only for prototypes, defective batteries and batteries for disposal.

Which eight tests does UN 38.3 include?

UN 38.3 comprises T1 altitude simulation, T2 thermal test, T3 vibration, T4 shock, T5 external short circuit, T6 impact or crush, T7 overcharge and T8 forced discharge. Cells go through T1 to T6 and T8, rechargeable batteries T1 to T5 and T7, primary batteries T1 to T5. A test item passes only without fire, rupture, leakage or disassembly and within the limits for mass loss and voltage.

What is the UN 38.3 test summary, and is there a UN 38.3 certificate?

The test summary shows that a battery type has passed the tests. It is often called a UN 38.3 certificate, but it is not an official certificate. The tests are usually carried out by specialized, often accredited test laboratories. Manufacturers and subsequent distributors must make the test summary available (ADR 2.2.9.1.7.1 (g)).

How long is a UN 38.3 test valid?

UN 38.3 has no expiry date. A retest is required when the tested type changes; section 38.3.2.2 of the UN Manual lists, among other things, a change in nominal energy or an increase in nominal voltage of more than 20% each, and changes to cell chemistry, design or protection circuit. What matters is that the tested type and the shipped type are the same.

How are prototypes transported without UN 38.3?

Under special provision 310 (ADR, IMDG Code) or A88 (IATA). It covers pre-production prototypes carried for testing and production runs of no more than 100 cells or batteries. Under P910 or LP905, each cell or battery goes into its own inner packaging, and the outer packaging meets packing group II. In air freight, this is only possible on cargo aircraft and with approval from the authorities of the state of origin and the state of the operator.

Read more: Logistics for battery manufacturers

What happens if there is no test summary?

Then the battery cannot be carried as regular UN 3480 or UN 3481. The special routes remain: prototypes and small production runs under special provision 310 (P910/LP905), damaged or defective batteries under special provision 376 (P908/LP904, critically defective ones P911/LP906 or BAM conditions) and batteries for disposal under special provision 377 (P909). We work out with you which route fits.

Does the European Battery Hub carry out UN 38.3 testing?

No. UN 38.3 testing is carried out by test laboratories on behalf of the manufacturer; the European Battery Hub is not a test laboratory and does not issue UN 38.3 evidence. We transport and store batteries whose type has been tested and carry prototypes via the special route provided for them; we arrange the transport of defective batteries and batteries for disposal through a specialized partner.

Read more: Dangerous goods transport for batteries

Ship tested batteries safely?

Tell us the battery type, quantity and destination. We answer your questions on classification and special routes and handle transport and storage. We get back to you within 24 hours on business days.

Response
within 24 hours on business days