Marcel Niebuhr
Head of Business Development
UN 38.3 is the required transport test for lithium batteries. This guide explains the eight tests T1 to T8 and the exceptions.
UN 38.3 is a type test for lithium batteries (since ADR 2025 also sodium-ion): every cell and battery type must pass the required tests T1 to T8 before regular carriage as Class 9 dangerous goods. Testing is done by a test laboratory on behalf of the manufacturer; the European Battery Hub (EBH) in Paderborn, Germany, transports tested batteries and advises on the exceptions.
It is not a product quality test but a transport safety test. It makes sure a battery withstands low pressure, temperature changes, vibration, shocks and electrical faults without fire, rupture, leakage or a short circuit. The ADR regulations (road), RID (rail), the IMDG Code (sea) and the IATA DGR (air) all require it.
The evidence is the test summary, which manufacturers and subsequent distributors must make available (ADR 2.2.9.1.7.1 (g), clarified in ADR 2025). It is often called a "UN 38.3 certificate", but it is not a certification issued by an authority or certification body.
The tests are run in a fixed order on the same test samples. T1 to T5 are carried out one after another on the same sample, T6 to T8 on further samples. The values below are typical test conditions from the UN Manual.
Behavior at low air pressure (for example air freight in an unpressurised cargo hold)
11.6 kPa, at least 6 hours at 20 °C
Stress from rapid, extreme changes in temperature
Cycling between +72 °C and -40 °C, 10 cycles
Vibration during transport
Sine sweep 7 Hz to 200 Hz and back, 3 hours per axis, 3 axes
Impacts from handling and transhipment
e.g. 150 g / 6 ms (small cells), each direction and axis
Reaction to an external short circuit
≤ 0.1 Ω at 57 °C, then 6 hours of observation
Internal short circuit from deformation of the casing
Impact: 9.1 kg from 61 cm, for cylindrical cells of 18 mm diameter or more. Crush up to 13 kN, for prismatic, pouch, coin and cylindrical cells under 18 mm
Behavior during overcharge
Twice the recommended charging current, 24 hours, 7 days of observation
Behavior during deep discharge / reverse polarity
Forced discharge of the cell (cell test)
Not every test item goes through all eight tests.
| Test item | Tests |
|---|---|
| Cells | T1 to T6 and T8 |
| Rechargeable batteries | T1 to T5 and T7 |
| Primary batteries (non-rechargeable) | T1 to T5 |
01 / 08
Only when a cell or battery type passes the required tests T1 to T8 may it be carried as regular Class 9 dangerous goods.
The test sample is exposed to a low pressure of 11.6 kPa for at least six hours, which corresponds to an altitude of about 15,000 meters. This simulates transport in an unpressurised cargo hold. No leakage, venting, rupture or ignition is permitted.
The battery goes through ten cycles of rapid change between +72 °C and -40 °C. This checks the seal and the mechanical integrity under thermal stress. Large cells and batteries dwell longer at each temperature step.
In the vibration test, the sample goes through a sine sweep from 7 Hz to 200 Hz and back, three hours each in three mutually perpendicular axes. In the shock test, defined shock pulses are applied in the positive and negative direction of every axis. Both reproduce the stresses from the vehicle, transhipment and handling.
The battery, conditioned to 57 °C, is short-circuited through a resistance of no more than 0.1 ohm and then observed for at least six hours. The external temperature must not exceed 170 °C, and no disassembly, rupture or ignition is permitted.
Here an internal short circuit is forced by mechanical deformation. In the impact test, a 9.1 kg mass is dropped from 61 cm onto the cell; this applies to cylindrical cells of 18 mm diameter or more. Prismatic, pouch, coin and cylindrical cells under 18 mm in diameter are crushed up to 13 kN instead. The surface temperature must not exceed 170 °C.
The overcharge test (for rechargeable batteries only) checks behavior when charging at twice the recommended current for 24 hours, followed by seven days of observation. The forced discharge test (cells) checks deep discharge and reverse polarity. No fire may occur within seven days.

Since 1 January 2020, manufacturers and subsequent distributors of cells and batteries have had to make a test summary available (ADR 2.2.9.1.7.1 (g), clarified in ADR 2025). It states, among other things, the battery type, watt-hours or lithium content, the tests carried out, the edition of the UN Manual applied and the test laboratory.
In logistics, it is the entry ticket: without a test summary, a battery cannot be carried as regular UN 3480 or UN 3481. If it is missing, we work out with you which documents the manufacturer needs to provide or whether an exception applies.
A UN 38.3 test has no expiry date. A new test is required when the type changes. Section 38.3.2.2 of the UN Manual lists, among other things, a change in nominal energy of more than 20%, an increase in nominal voltage of more than 20% and changes to the cell chemistry, design or protection circuit that may affect the test result. What matters is that the tested type and the type shipped are the same.
Under section 38.3.5 of the UN Manual, every test summary includes:
Since ADR 2025, UN 38.3 also applies to sodium-ion batteries.
ADR-compliant transport of tested class 9 lithium batteries to more than 40 countries.
See dangerous goods transportThe difference between batteries shipped on their own and batteries in, or packed with, equipment.
See class 9 dangerous goodsCertified storage of tested lithium-ion batteries in the hazardous materials warehouse.
See battery logisticsTalk directly with our business development team.
We will get back to you within 24 hours on business days.

Head of Business Development

Business Development Manager

Business Development Manager
Yes. UN 38.3 is the transport test for lithium batteries from the UN Manual of Tests and Criteria. The ADR regulations, RID, IMDG Code and IATA DGR all require every cell and battery type to have passed it before being carried as regular Class 9 dangerous goods. Special routes without testing exist only for prototypes, defective batteries and batteries for disposal.
UN 38.3 comprises T1 altitude simulation, T2 thermal test, T3 vibration, T4 shock, T5 external short circuit, T6 impact or crush, T7 overcharge and T8 forced discharge. Cells go through T1 to T6 and T8, rechargeable batteries T1 to T5 and T7, primary batteries T1 to T5. A test item passes only without fire, rupture, leakage or disassembly and within the limits for mass loss and voltage.
The test summary shows that a battery type has passed the tests. It is often called a UN 38.3 certificate, but it is not an official certificate. The tests are usually carried out by specialized, often accredited test laboratories. Manufacturers and subsequent distributors must make the test summary available (ADR 2.2.9.1.7.1 (g)).
UN 38.3 has no expiry date. A retest is required when the tested type changes; section 38.3.2.2 of the UN Manual lists, among other things, a change in nominal energy or an increase in nominal voltage of more than 20% each, and changes to cell chemistry, design or protection circuit. What matters is that the tested type and the shipped type are the same.
Under special provision 310 (ADR, IMDG Code) or A88 (IATA). It covers pre-production prototypes carried for testing and production runs of no more than 100 cells or batteries. Under P910 or LP905, each cell or battery goes into its own inner packaging, and the outer packaging meets packing group II. In air freight, this is only possible on cargo aircraft and with approval from the authorities of the state of origin and the state of the operator.
Read more: Logistics for battery manufacturers
Then the battery cannot be carried as regular UN 3480 or UN 3481. The special routes remain: prototypes and small production runs under special provision 310 (P910/LP905), damaged or defective batteries under special provision 376 (P908/LP904, critically defective ones P911/LP906 or BAM conditions) and batteries for disposal under special provision 377 (P909). We work out with you which route fits.
No. UN 38.3 testing is carried out by test laboratories on behalf of the manufacturer; the European Battery Hub is not a test laboratory and does not issue UN 38.3 evidence. We transport and store batteries whose type has been tested and carry prototypes via the special route provided for them; we arrange the transport of defective batteries and batteries for disposal through a specialized partner.
Read more: Dangerous goods transport for batteries
Tell us the battery type, quantity and destination. We answer your questions on classification and special routes and handle transport and storage. We get back to you within 24 hours on business days.