Thermal runaway is a self-accelerating chain reaction inside a lithium-ion cell. This guide explains triggers, warning signs and extinguishing.
Thermal runaway is a self-accelerating chain reaction inside a lithium-ion cell: the cell generates more heat than it can release, vents flammable and toxic gases and can drag neighboring cells along. Water cools and stops the spread, but it does not reliably end the reaction in the affected cell. The European Battery Hub (EBH) in Paderborn, Germany, therefore cools affected zones and isolates critical batteries in the containment box.
A thermal runaway almost always begins with one of three types of trigger, which all lead to the same mechanism, an internal short circuit and uncontrolled heating:
Latent damage is particularly treacherous: a cell weakened by a mechanical impact can look perfectly normal from the outside and only go into thermal runaway hours or days later. This is exactly why safety at the European Battery Hub begins before the warehouse, at the inspected inbound inspection gate.
A thermal runaway does not happen all at once, it develops in recognizable phases. The earlier it is detected in this chain, the sooner it can be contained before a whole storage unit is affected:
Which cell chemistry is more at risk? Cells with nickel-rich cathodes (NMC, NCA) release oxygen when the cathode breaks down and react particularly violently. Lithium iron phosphate (LFP) releases far less oxygen and is considered thermally more stable, but it can also go into thermal runaway and release flammable gases.
The three-stage fire protection concept of the European Battery Hub addresses these phases: it detects heating early, extinguishes with FM Global sprinklers and isolates critical batteries. What this means for companies that store batteries themselves is explained in how to store lithium batteries safely.
The four phases of thermal runaway at a glance, each with its typical warning sign and the countermeasure the European Battery Hub has in place for it.
At the inbound inspection gate, batteries pass a temperature check before they enter the warehouse; goods too large for the gate go through their own goods receipt processes. This way, cells with latent damage are caught instead of becoming a risk on the rack.
Schematic curve, not measured data. The documented value is the onset of self heating at around 80 °C to 120 °C.
The most effective protection is to detect the event before an open flame appears. During the self heating and venting phases a cell sends out measurable warning signs: a rising surface temperature and escaping gases. At the European Battery Hub, the rising temperature is made visible by a thermal imaging drone that flies through the warehouse around the clock with a thermal camera and feeds its scans into a digital twin. A fire alarm system and gas detection also monitor the warehouse. The aim is to isolate critical batteries while this is still possible in a controlled way, rather than only once the fire is burning.
Water cools and stops the spread, but it does not reliably end the reaction in the affected cell. A generalist offers storage space, a specialist controls the risk.
That is why the European Battery Hub acts at every stage of the chain, from goods receipt to the emergency response plan.
At the inbound inspection gate, batteries pass a temperature check before they enter the warehouse; goods too large for the gate go through their own goods receipt processes. This way, cells with latent damage are caught instead of becoming a risk on the rack.
The thermal imaging drone checks the warehouse around the clock with a thermal camera, and a fire alarm system and gas detection monitor it as well. The aim is to detect unusual temperatures during the self heating and venting phases, before any open flame.
The FM Global sprinkler system, supplied by a fire water tank holding around 1 million liters, extinguishes the fire. Smothering barely helps because the cell feeds the reaction from within. Water cools and stops the spread, but it does not reliably end the reaction in the affected cell, so the battery is also isolated.
Critical cells go into the containment box (Liio-Box, BAM 15854): up to 1,240 °C inside, a maximum of 52 °C outside, with a stainless steel sump for electrolytes, so propagation is limited to that one unit.
If a critical condition arises despite all prevention, a clearly defined sequence takes over: detect, contain, recover and transport out. The European Battery Hub does not store damaged or runaway batteries in the hazardous materials warehouse. How they are handled in practice is shown on the page on damaged and defective lithium batteries (DDLB). The affected battery is recovered into the containment box, and we arrange its removal through a specialized partner. The full emergency procedure is described in the emergency response plan, and the storage environment in the hazardous materials warehouse.
Talk directly with our business development team.
We will get back to you within 24 hours on business days.

Head of Business Development

Business Development Manager

Business Development Manager
A thermal runaway is an exothermic chain reaction inside a lithium-ion cell that sustains and accelerates itself. Above a critical temperature the cell generates more heat than it can dissipate, which sets off further chemical decomposition reactions. The temperature then rises faster and faster, flammable gases escape, the cell can ignite or burst, and the released heat can drag neighboring cells into the reaction.
No. Thermal runaway is the self-accelerating heating inside a cell; a battery fire is one possible result. A cell in thermal runaway can vent gases without visible flames, and a fire can start minutes or hours later. Detecting the heating early is therefore the most effective protection.
There are three types of trigger, which all lead to an internal short circuit and uncontrolled heating: mechanical (crushing, puncturing or drop damage that injures the separator), electrical (overcharging, deep discharge, an external short circuit or a cell defect) and thermal (external overheating, for example from a nearby fire). Latent damage is especially dangerous, because a cell can go into runaway only hours or days later.
Yes, a previously damaged lithium battery can ignite without any external cause. The reason is usually latent damage, such as a separator injured by a drop or impact, a manufacturing fault or damage from overcharging or deep discharge. This can develop into an internal short circuit that leads to thermal runaway hours or days later. That is why the European Battery Hub checks batteries for temperature and condition at the inbound inspection gate, checks the warehouse around the clock with thermal imaging and monitors it with a fire alarm system and gas detection.
Read more: Inbound inspection gate, Thermal imaging drone
Only to a limited extent. Smothering barely works because the cell feeds the reaction from within and, depending on its chemistry, releases oxygen. Water is still the key extinguishing agent: it cools and stops the spread, but it does not reliably end the reaction in the affected cell, which can reignite hours later. The rule is therefore: cool and isolate the battery, at the European Battery Hub with FM Global suppression and the containment box.
A thermal runaway gives warning before it burns: in the self heating phase the surface temperature rises, and in the venting phase flammable gases escape. Both are measurable. At the European Battery Hub, a thermal imaging drone checks the warehouse around the clock with thermal imaging and makes unusual temperatures visible, and a fire alarm system and gas detection monitor the warehouse as well. The aim is to isolate critical batteries before an open flame appears.
Prevention works on several levels: an incoming inspection for temperature and condition, correct charging conditions and maintenance charging, FM Global fire suppression, and early detection by thermal imaging, a fire alarm system and gas detection. Damaged or suspicious cells do not belong in the normal stock; they go straight into a suitable safety container such as the containment box.
A defined sequence takes effect: detect, contain, capture and remove. The sprinkler system extinguishes the fire; the critical battery goes into the containment box with BAM specification 15854 (up to 1,240 °C inside, no more than 52 °C outside), and we arrange its removal through a specialized partner.
Read more: Emergency response plan
Do you store or transport lithium-ion batteries? We will show you how incoming battery inspection, thermal monitoring, fire suppression and the containment box work together at the European Battery Hub, and get back to you within 24 hours on business days.